Banner SI-HG63 Hinge Style Switches Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Ausrüstung Banner SI-HG63 Hinge Style Switches herunter. Banner SI-HG63 Hinge Style Switches User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 14
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Datasheet
SI-HG(Z)63 Series Safety Interlock Switches attached with a load-bearing hinge
Safety switch is integrated into a highly robust PBT housing and screwed onto the fine-cast stain-
less steel or zinc die-cast hinge
Safety switching point is repositionable
Right-hinge QD, left-hinge QD, and right-angle QD hinge models available; switches can also be
converted to operate from the opposite side
A non-switching blank hinge is also available. See Blank Hinge on page 13.
Switch components are protected from mechanical impact for superior performance to actuator-
activated safety switches; rated IEC IP67
Hinge operates to a full 270° range of motion; safety switching point (guard-closed position) is
adjustable over the full 0 to 270°operating range
Stainless steel hinge supports a load of 1800 N (180 Kg ). Zinc die-cast hinge supports a load of
1200 N (120 Kg)
When properly interfaced or used with an appropriate controller, two SI-HG(Z)63 switches on an
individual gate or guard can achieve safety category 4, per ISO 13849-1 (EN 954-1)
Typical applications include hinged covers and guards on machines and hinged gates in safety
fencing systems
Models
Model Construction Housing Style/QD Connection
SI-HG63FQDR Stainless Steel
Inline QD—With QD facing down, switch is mounted on right side of hinge
SI-HGZ63FQDR Zinc Die-cast
SI-HG63FQDL Stainless Steel
Inline QD—With QD facing down, switch is mounted on left side of hinge
SI-HGZ63FQDL Zinc Die-cast
SI-HG63FQDRR Stainless Steel
Right-Angle QD—With switch body down, switch is mounted on right side of hinge
SI-HGZ63FQDRR Zinc Die-cast
33
21
11
rd/bu
gn
rd
34
22
12
rd/bk
rd/ye
rd/wh
Figure 1. Contact Configuration
1
(Gate Closed State)
rd/bu
rd
rd/bk
rd/ye
rd/wh
33
21
11
gn
34
22
12
Figure 2. Contact Configuration
1
(Gate Open State)
1.5 Nm
Set Point
1.5 Nm
11-12
21-22
33-34
Safety
Safety
Non-Safety
Contacts: Open Closed Transition
Figure 3. Switching Diagram
1
Terminals 33 and 34 are non-safety.
Hinge Wing Safety Interlock Switches
Datasheet
129465_web Rev.
D
3/4/2014
Seitenansicht 0
1 2 3 4 5 6 ... 13 14

Inhaltsverzeichnis

Seite 1 - 3/4/2014

DatasheetSI-HG(Z)63 Series Safety Interlock Switches attached with a load-bearing hinge• Safety switch is integrated into a highly robust PBT housing

Seite 2 - Overview

SpecificationsContact Rating3 A @ 230V ac max., 1.0 A @ 24V dc max.2.5 kV max. transient toleranceEuropean Rating:Ui = 250VUe = 230V AC, 24V DCIthe =

Seite 3 - Mechanical Installation

ExampleA guard with a 40 mm aluminum profile (A) and a width of 900 mm (B) is safeguarded by SI-HG63.. safety interlocking switch. Theswitching point

Seite 4 - Setting the Switch Point

4.0 mm(0.16")19.5 mm(0.77")147.0 mm(5.79")45.0 mm(1.77")63.0 mm(2.48")6.3 mm(0.25")M12X118 mm(0.71")33.0 mm(1.30)&q

Seite 5 - Adjustment

Blank HingeModel Construction Description DimensionsSI-HG63A Stainless Steel Blank hinge; same mechanical specificationsas SI-HG(Z)63 Series hinge swi

Seite 6

IEC 61508 Functional Safety of Electrical/Electronic/Programmable Electronic Safety-Related SystemsEC Declaration of Conformity (DOC)Banner Engineerin

Seite 7 - Electrical Installation

NOTE: This symbol for a positive-opening safety contact (IEC 60947-5-1) is used in the switching dia-gram to identify the point in actuator travel w

Seite 8 - Connection to a Machine

CAUTION: End-of-Travel StopDo not use the safety switch as a mechanical or end-of-travel stop.The movement or rotation of the guard must be limited su

Seite 9 - Maintenance

3. Verify that the axis of rotation is identical for all hinges used. Typically, this is accomplished by using a straight edge along the longflat edge

Seite 10 - Specifications

Figure 7. Red to green color ring7. Insert the supplied plugs into the topside of the hinge, and the bottom of the switch, to protect the switch from

Seite 11 - Dimensions

Figure 10. Remove the plugs3. Remove the hinge portion from the switch.Figure 11. Remove the hinge4. Lift the red plastic washer from the switch. Disc

Seite 12 - Cordsets

Figure 14. Align to "B"7. Press the switch element into the enclosure again until it reaches the internal stop.8. Install a new red plastic

Seite 13 - U.S. Application Standards

Connection to a MachineElectrical connection is via a 6-pin dual-key M12/micro-style QD and cordsets (see Cordsets on page 12).Perform a risk assessme

Seite 14

When multiple safety interlock switches are series connected, the failure of one switch in the system may be masked or not be detectedat all. The foll