Banner RP-LM40 Rope Pull Switches Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Spezialmaschinen Banner RP-LM40 Rope Pull Switches herunter. Banner RP-LM40 Rope Pull Switches User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Datasheet
RP-LM40 Series 40 mm Limit-Switch-Style Switches with Rope Actuators
Positive-opening safety contacts (IEC 60947-5-1), not dependent upon
springs
Standard limit-switch housing (EN 50041)
Heavy-duty die cast metal housing, rated IP65, suitable for demanding
industrial environments
Rope spans up to 6 m (20 ft)
Both safety contacts are closed with normal rope tension; one contact
opens when rope is pulled, the other contact opens if rope breaks (or if
tension is reduced from normal amount)
Long life, switch rated at 1 million mechanical operations, minimum
Two available models, trip and latch
Protective Earth Terminal (IEC 60947-1)
Model
Actuation Max. Rope
Length
Run Position Cable Pulled Cable Break Switching
Diagram
RP-LM40D-6 Trip
6 m (20 ft)
25 26
13 14
25 26
13 14
25 26
13 14
13-14
25-26
Break
Pull
50N
70N
0 (0)
1.6 (0.06)
3.6 (0.14)
4.4 (0.17)
5.0 (0.20)
mm (in)
RP-LM40D-6L Latch
13-14
25-26
Break
Pull
50N
70N
0 (0)
1.2 (0.05)
3.2 (0.13) Latch
4.8 (0.19)
mm (in)
Contacts: Open Closed Transition
RP-LM40 Series Rope Pull Switches
P/N 62082 Rev. C 23 January 2014
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - Datasheet

DatasheetRP-LM40 Series 40 mm Limit-Switch-Style Switches with Rope Actuators • Positive-opening safety contacts (IEC 60947-5-1), not dependent upons

Seite 2 - Overview

NOTE: This symbol for a positive-opening safety contact (IEC 60947-5-1) is used in the switchingdiagram to identify the point in actuator travel whe

Seite 3 - Mechanical Installation

WARNING: Not a Safeguarding DeviceAn Emergency Stop Device is not considered a safeguarding device because it requires anovert action by an individual

Seite 4 - Maintenance/Checkout

150 mm(6") max.6 m(20') max.3 m(10') max.25 mm(1") min.400 mm (16") max.for Actuation of SwitchNOTE: Force to actuate must

Seite 5 - Specifications

• Repair any loose or damaged hardware, worn/frayed rope (cable), missing red rope sheathing or flags/markers (ifused)• Remove or clean off any contam

Seite 6 - Accessories

Dimensions30.0 mm(1.18")40.0 mm(1.58")Ø5.2 mm(0.20")M20 x 1.560.0 mm(2.36")74.5 mm(2.94")7.5 mm(0.30")50.0 mm(1.97"

Seite 7 - Assembly Components

Conduit AdaptersModel Size Thread Conversion Dimensions Used WithSI-QM-M20½ in-14 NPTMetalM20 × 1.5 to ½in-14 NPT23.0 mm(0.91")M20 x 1.524.0 mm(0

Seite 8

Model Quantity Description Eye BoltRPA-EB1-1 1 ¼"-20 Eye bolt (3" bolt shaft)Model Quantity Description PulleyRPA-P1-1 1 Hanging pulley for