3
Top view
Dimensions, Q85 Series sensors*
Bottom view
*Emitter units have same dimensions but no SENSITIVITY control, logic
timing adjustments, or indicator LEDs.
The output timing logic function (on sensor models with T9 model
number sufx) is selected at the timing logic programming switches,
according to the table (below). The output timing logic delays are
set at the single-turn time adjustment potentiometer. When the tim-
ing function involves more than one time (as in ON and OFF delay,
ON-delayed one-shot, and ON-delayed limit timer functions), the
potentiometer sets both times to the same value.
Logic function Switch: SW1 SW2 SW3
ON and OFF delays (both) 0 0 0
ON delay (only) 0 0 1
OFF delay (only) 0 1 0
No delays 0 1 1
ON delayed one-shot 1 0 0
ON delayed limit timer 1 0 1
One-shot 1 1 0
Limit timer 1 1 1
Timing Logic Selection and Hookup
Light/dark Operate switch
detail (basic on/off models):
Timing Logic Programming
switch detail (T9 models),
see table (left):
With the light/dark operate switch (all models) set to light operate
(L.O.), the sensor's output is energized when the sensor sees its own
modulated light source. In the dark operate (D.O.) position, the
output is energized when the sensor does not see its modulated light
source. Sensor sensitivity is set at the single-turn sensitivity adjust-
ment potentiometer.
Shown with SMB85B mounting bracket
(included with sensor)
Shown with SMB85R mounting bracket
(p/n 32798, order separately)
Q85 Series ac/dc Sensors