Printed in USA 02/05 P/N 112153 rev. C
QL55 Series Luminescence Sensor
Self-contained, microprocessor-based luminescence sensor
Features
Self-contained design in a robust, compact metal housing
High sensitivity
Microprocessor-controlled
Senses luminescent marks, even on luminescent backgrounds
Senses luminescence on reflective surfaces, such as ceramic, metal, or mirrored
glass
Easy-to-set sensing threshold
Fast 250-microsecond sensing response time; high 2 kHz switching frequency
Switch-selectable NPN or PNP discrete output, plus 0 to 5.5V dc analog output
Switch-selectable output OFF-delay
3-position swivel QD connector
Models
* Mating cable required; see back cover for cable options.
Models
Sensing
Range
Cable/
Connector*
Supply
Voltage
Outputs Sensor Performance
QL55M6XD15BQ
9 to 18 mm
(0.35" to 0.71")
4-pin Euro-style
(M12)
QD connector
with 3-position
swivel
(locking
screw-secured)
10 to
30V dc
One selectable
NPN or PNP
discrete plus
one
0 to 5.5V dc
analog
QL55M6XD30BQ
20 to 40 mm
(0.79" to 1.57")
QL55M6XD50BQ
40 to 75 mm
(1.57" to 2.95")
WARNING . . .
Not To Be Used for Personnel Protection
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current
Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
!
Relative Received Signal
Sensing Distance
0
0
10 mm
(0.4")
20 mm
(0.8")
30 mm
(1.2")
40 mm
(1.6")
50 mm
(2.0")
20%
40%
60%
80%
100%
Relative Received Signal
Sensing Distance
0
0
10 mm
(0.4")
20 mm
(0.8")
30 mm
(1.2")
40 mm
(1.6")
50 mm
(2.0")
20%
40%
60%
80%
100%
Relative Received Signal
Sensing Distance
0
40 mm
(1.6")
30 mm
(1.2")
50mm
(2.0")
60 mm
(2.4")
70 mm
(2.8")
80 mm
(3.2")
20%
40%
60%
80%
100%
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - Features

Printed in USA 02/05 P/N 112153 rev. CQL55 Series Luminescence SensorSelf-contained, microprocessor-based luminescence sensorFeatures• Self-contain

Seite 2 - Overview

QL55 Series Luminescence Sensor2 P/N 112153 rev. C Banner Engineering Corp. • Minneapolis, MN U.S.A.www.bannerengineering.com • Tel: 763.544.

Seite 3 - Sensor Configuration

QL55 Series Luminescence Sensor P/N 112153 rev. C 3 Banner Engineering Corp. • Minneapolis, MN U.S.A.www.bannerengineering.com • Tel: 763.544.

Seite 4 - Setting NPN / PNP Output

QL55 Series Luminescence Sensor4 P/N 112153 rev. C Banner Engineering Corp. • Minneapolis, MN U.S.A.www.bannerengineering.com • Tel: 763.544.

Seite 5 - Sensor Operation

QL55 Series Luminescence Sensor P/N 112153 rev. C 5 Banner Engineering Corp. • Minneapolis, MN U.S.A.www.bannerengineering.com • Tel: 763.544.

Seite 6 - Specifications

QL55 Series Luminescence Sensor6 P/N 112153 rev. C Banner Engineering Corp. • Minneapolis, MN U.S.A.www.bannerengineering.com • Tel: 763.544.

Seite 7 - Dimensions

QL55 Series Luminescence Sensor P/N 112153 rev. C 7 Banner Engineering Corp. • Minneapolis, MN U.S.A.www.bannerengineering.com • Tel: 763.544.

Seite 8 - Accessory Mounting Brackets

Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengi

Kommentare zu diesen Handbüchern

Keine Kommentare