DatasheetSelf-checking ergonomic actuating devices-RB1E02 without E-Stop• Ergonomic design for reduced hand, wrist, and arm stresses associated withre
SpecificationsPowerSupply Voltage and Current: 10 to 30 V dcPower Consumption: approx. 1.8 W @ 24 V dc (with no output load),for each STBSupply Protec
240.0 [9.46"]23.5 [0.93"]38.0 [1.50"]2x Ø28.0 [1.10"] (3/4" NPT) Knockout 2x Ø22.0 [0.87"] (1/2" NPT) Knockout87.0
Model DescriptionSTBA-RB1-MB3 • Swivel-mount bracket; mounts to telescoping stands below• Holes for radial adjustment, 0°–30° in 10° increments• Made
Model DescriptionSTBA-RB2-MB3 • Swivel-mount bracket; mounts to telescoping stands below• Holes for radial adjustment, 0°–30° in 10° increments• Made
Model DescriptionSTBA-RB1-S2 • Free-standing, telescoping stand; locates touch buttons 800to 1232 mm (31.5" to 48.5") above the floor surfac
DUO-TOUCH® SG Two-Hand Control Modules, STB CompatibleN.C. = Normally Closed, N.O. = Normally OpenModelSupplyVoltageInputsSafetyOutputsOutputRatingAux
8-Pin Mini-style CordsetsThe following cordsets have an 8-pin mini-style connection on one end and are made of 20 gauge wire.Models Length Banner Cabl
8-LM2T-AU120Metal mounting adapter for metal button8-LM2T-C01• Normally closed (N.C.) positivelydriven contact element• Direct (positive) opening oper
Banner Engineering Corp. has attempted to provide complete application, installation, operation, and maintenanceinstructions. In addition, we suggest
STB Series Touch Button LED IndicatorsOutput, Fault (green) Steady ON when button is activatedOFF when button is not activatedFlashing when a fault co
Mechanical InstallationSee elbowheight tableSeparation distance (D )s±30°Figure 1. Run Bar LocationMount the DUO-TOUCH Run Bar to maximize its ergono
WARNING: Location of Touch Button ControlsHand controls must be mounted a safe distance from moving machine parts, as determinedby the appropriate sta
Separation Distance (Ds) CalculationThe following example illustrates the use of the formula to calculate separation distance for a part-revolution cl
Figure 5. Use the slots in the run bar housing to hold the cover for the terminal connection8-Pin Mini-Style Output QD ConnectorMale Face ViewMating C
Solid-State10-30V dcV+ V+bnblwhbuMicro-Controller1Micro-Controller2+ –Figure 7. STB Touch Button Block DiagramLogicSTB2+ –STB1+ –LogicBrownBlackBlackB
WARNING: Do Not Use System Until Checkouts Are VerifiedIf all of the described checks cannot be verified, do not attempt to use the two-hand controlsa