EZA-S Series Enclosures
For mounted protection of EZ-SCREEN
Point and Grid Sensors and Mirrors
Features
12 models available: 5 with corner mirrors, 2 with return 45° mirrors for access
guarding applications; 5 to house EZ-SCREEN Point and Grid Sensors
Models meet ANSI/RIA 15.06 and ISO 13855 standards for beam spacing
Robust aluminum housing with a tough safety yellow finish
Independently adjustable mirrors to simplify alignment
Circular bubble level on top of enclosure with three leveling screws in base
Base allows enclosure to rotate up to 20°
Banner EZA-S Series Enclosures are designed specifically for use with Banner EZ-SCREEN
Point and Grid models. The enclosures are constructed of a powder coated extruded
aluminum housing with an anodized aluminum top plate and mounting base. The
enclosures have leveling and rotational positioning capabilities. Units with mirrors have
3 adjusting screws per mirror to optimize beam direction. The enclosures are available in
12 different models to accommodate ANSI/RIA 15.06 and ISO 13855 beam spacing
standards. The rear-surfaced glass mirrors are rated at 85% efficiency per mirror and
reduce maximum range by 8% per mirror.
Printed in USA 02/12
P/N 109308 rev. B
NOTE . . .
Reduced
Sensing Range
Sensing range is reduced to
85% efficiency per mirror.
WARNING . . .
Maintain Required Separation Distance
The light screen produced by the optical safety system sensors must be placed at a minimum safe distance from the
dangerous motion of the machine being guarded. This necessary minimum distance is called the separation distance, and is
discussed in Section 3 of the appropriate manuals. Failure to calculate this distance correctly and to maintain minimum
separation distance can result in serious injury.
Models*
Enclosure
Height
L1**
No. of
Windows
Distance from Floor
to Bottom Window
L2**
Protected
Height
Application
Standard
EZ-SCREEN
Models
EZA-S300
1543 mm
(60.75")
4
300 mm
(11.8")
900 mm
(35.4")
ANSI/RIA R15.06
ISO 13855
SG(XL)P4-300
EZA-S400
1238 mm
(48.75")
3
300 mm
(11.8")
800 mm
(31.5")
ANSI/RIA R15.06
ISO 13855
SG(XL)P3-300
EZA-S300-M
EZA-S400-M
EZA-S533
1543 mm
(60.75")
3
305 mm
(12.0")
1066 mm
(42.0")
ANSI/RIA R15.06
SG(XL)P3-533
EZA-S533-M
EZA-S500
1035 mm
(40.75")
2
400 mm
(15.8")
500 mm
(19.7")
ISO 13855
SG(XL)P2-500
EZA-S500-M45
EZA-S500-M
EZA-S584
1238.2 mm
(48.75")
2
305 mm
(12.0")
584 mm
(23.0")
ANSI/RIA R15.06
SG(XL)P2-584
EZA-S584-M45
EZA-S584-M
Models
Distance
Between Beams
L3**
300 mm
(11.8")
400 mm
(15.8")
533 mm
(21.0")
500 mm
(19.7")
584 mm
(23.0")
*Model numbers with suffix “M” include vertical mirrors for perimeter-guarding applications.
Model numbers with suffix “M45” include two 45°-mounted mirrors for access-guarding applications.
**Refer to Figure 1.
SP(XL)P1
SP(XL)P1
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - EZA-S Series Enclosures

EZA-S Series EnclosuresFor mounted protection of EZ-SCREEN™Point and Grid Sensors and MirrorsFeatures• 12 models available: 5 with corner mirrors, 2

Seite 2

EZA-S Series EnclosuresBanner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email:

Kommentare zu diesen Handbüchern

Keine Kommentare