LIGHT GAUGING
ULTRASONIC
QT50U
S18U
QS18U
T30U/T30UX
M25U
T18U
Q45U
Q45UR
MEASURING
ARRAYS
RADAR
More information online at bannerengineering.com 323
Photoelectrics
Sensors
Fiber Optic
Sensors
Special Purpose
Sensors
Measurement &
Inspection Sensors
Vision
Wireless
Lighting &
Indicators
Safety
Light Screens
Safety
Laser Scanners
Fiber Optic
Safety Systems
Safety Controllers &
Modules
Safety Two-Hand
Control Modules
Safety Interlock
Switches
Emergency Stop &
Stop Control
U-GAGE
®
T30UX Specifications
Output Ratings
Discrete output models: 100 mA max.
OFF-state leakage current: NPN: < 200 µA @ 30V dc (see NOTE 1) PNP: < 10 µA @ 30V dc
ON-state saturation voltage: NPN: < 1.6V @ 100 mA PNP: < 3V @ 100 mA
Analog output models:
Analog Voltage Output: 2.5 kΩ min. load resistance
Minimum supply for a full 10V output is 12V dc (for supply voltages between 10 and 12, V out max. is
at least V supply -2)
Analog Current Output: 1 kΩ max. @ 24V input; max. load resistance = (Vcc-4)/0.02Ω
For current output (4-20 mA) models, ideal results are achieved when the total load resistance R = [(Vin – 4)/0.020]Ω. Example, at
Vin = 24V dc, R ≈ 1 kΩ (1 watt)
Output Protection Circuitry
Protected against short circuit conditions
Output Response Time
“A” suffix models: 45 milliseconds
“B” suffix models: 92 milliseconds
“C” suffix models: 135 milliseconds
Delay at Power-up
500 milliseconds
Temperature Effect
0.02% of distance/º C
Linearity (analog models)
0.25% of distance
Repeatability/Resolution
“A” suffix models: 0.1% of distance (0.5 mm min.)
“B” suffix models: 0.1% of distance (1.0 mm min.)
“C” suffix models: 0.1% of distance (1.5 mm min.)
Sensing Hysteresis
(discrete models)
“A” suffix models: 2 mm
“B” suffix models: 3 mm
“C” suffix models: 4 mm
Minimum Window Size
10 mm
Adjustments
Sensing window limits: TEACH-Mode conguration of near and far window limits may be set using the push button or
remotely viaTEACH input
Discrete output models:
Output Configuration: NPN, PNP, Normally Open (NO), Normally Closed (NC) select
Advanced configuration options: Push button enabled/disabled, temperature compensation enabled/disabled
Analog output models:
Response speed selection: Fast or Slow
Advanced configuration options: Analog output slope, push button enabled/disabled, temperature compensation enabled/disabled
Indicators
Green Power LED ON: Power ON, RUN mode
Red Signal LED: Target signal strength
Amber Output LED: Output enabled; sensor receiving a signal within the window limits
Amber Mode LED: Currently selected mode
Loss of Signal Indication
(analog models)
0 to 10V dc models: Analog output goes to 0V
4 to 20 mA models: Analog output goes to 3.6 mA
Construction
Housing: PBT polyester
Push buttons: polyester
Transducer: epoxy /ceramic composite
Environmental Rating
Leakproof design, rated IEC IP67 (NEMA 6)
Connections 2 m or 9 m shielded 4-conductor (with drain) PVC cable, 150 mm PUR Euro-style pigtail (QPMA), or 4-pin integral Euro-style
connector (Q8). QD cordsets ordered separately. See page 325.
Operating Conditions
Temperature: -40° to +70° C Relative humidity: 95% at 50°C non-condensing
Vibration and
Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60Hz max., double amplitude 0.06", maximum
acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half sine wave.
Application Notes
The temperature warmup drift upon power-up is less than 1% of the sensing distance.
Certifications
Hookup Diagrams
Discrete Models: MI13 (p. 761)
Analog Models: MI14 (p. 761)
NOTE 1: NPN < 200 µA for load impedance > 3 kΩ; for load current of 100 mA, leakage < 1% of load current
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com