Banner U-Gage Ultrasonic Sensor Bedienungsanleitung Seite 43

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 66
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 42
SENSORS
More information online at bannerengineering.com334
LIGHT GAUGING ULTRASONIC MEASURING ARRAYS RADAR
U-GAGE
®
Q45U Specifications
Performance Specifications
Short Range Long Range
Analog resolution or
discrete repeatability: ± 0.1% of sensing distance ± 0.1% of sensing distance
(± 0.25 mm min.) (± 0.5 mm min.)
Analog Linearity: 1% of full scale 1% of full scale
Temperature effect: 0.05% of sensing distance/ ° C with temp. comp. 0.05% of sensing distance/° C
0.2% of sensing distance/ ° C without temp. comp.
Min. window size: 10 mm 25 mm
Hysteresis (discrete output): 5 mm 10 mm
Effective Beam
See EBPC-1 to EBPC-4 on page 335.
Adjustments
The following may be selected by a 4-position DIP switch.
Discrete: Switch 1: Output normally open/normally closed (pump in/pump out)
Switch 2: High/Low level control mode or ON/OFF presence sensing mode
Switch 3 & 4: Response speed selection (digital lter)
Analog: Switch 1: Output slope positive or output slope negative
Switch 2: Current output mode or voltage output mode
Switch 3: Loss of echo min/max mode or loss of echo Hold Mode
Switch 4: Loss of echo min/max default output value
Indicators
Discrete: Three status LEDs:
Green: power ON
Yellow: outputs are conducting (Yellow LED also indicates programming
status during setup mode)
Red: indicates relative strength of received echo
Analog: Three status LEDs:
Green: power ON
Yellow: target is sensed within the window limits (Yellow LED also indicates programming status during setup mode)
Red flashing: indicates relative strength of received echo
5-segment moving dot LED indicates the position of the target within the sensing window.
See data sheet for detailed information.
Construction
Molded PBT polyester thermoplastic polyester housing, o-ring sealed transparent acrylic top cover, and stainless steel hardware.
Q45U sensors are designed to withstand 1200 psi washdown. The base of cabled models has a ½"-14NPS internal conduit thread.
Environmental Rating
Leakproof design is rated IEC IP67; NEMA 6P
Connections
2 m or 9 m attached cable, or 5-pin Mini-style or 5-pin Euro-style QD fitting. QD cordsets are ordered separately. See pages 335.
Operating Conditions
Temperature: -25° to +70° C Relative humidity: 100%
Vibration and
Mechanical Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60Hz max., double amplitude 0.06",
maximum acceleration 10G). Method 213B conditions H & I (Shock: 75G with unit operating; 100G for non-operation). Also meets
IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half sine wave.
Application Notes
Short Range: Min. target size: 10 x 10 mm aluminum plate at 500 mm
35 x 35 mm aluminum plate at 1.4 m
Long Range: Min. target size: 50 x 50 mm aluminum plate at 3 m
Discrete: Enable/Disable; Connect yellow wire to +5 to 24V dc to enable sensor and 0 to +2V dc to disable sensor. When the sensor
is disabled, the last output state is held until the sensor is re-enabled. The wire must be held to the appropriate voltage for at least 40
milliseconds for the sensor to enable or disable.
Certifications
Hookup Diagrams
MI18 (p. 762)
(cont’d)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com