Q40 Sensors ac-Voltage Series
Self-contained ac-operated sensors
* Standard 2 m (6.5') cable models are listed.
9 m (30') cable: add suffix “W/30” (e.g., Q403E W/30).
4-pin Micro-style QD models: add suffix “Q1” (e.g., Q403EQ1). A model with a QD connector requires a mating cable.
Sensing Mode Range LED Output Model*
Opposed
60 m (200')
Infrared
950 nm
Q403E
LO
Q40AW3R
DO
Q40RW3R
Polarized
Retroreflective
6 m (20')
Visible Red
680 nm
LO
Q40AW3LP
DO
Q40RW3LP
Fixed-Field
200 mm (8") cutoff
Infrared
880 nm
LO
Q40AW3FF200
DO
Q40RW3FF200
400 mm (16") cutoff
LO
Q40AW3FF400
DO
Q40RW3FF400
600 mm (24") cutoff
LO
Q40AW3FF600
DO
Q40RW3FF600
P
Features
Featuring EZ-BEAM
®
technology, the specially designed optics and electronics
provide reliable sensing without the need for adjustments
Rectangular 40 mm PBT polyester (plastic) housing with 30 mm threaded
mounting base in opposed, retroreflective or fixed-field modes
Completely epoxy-encapsulated to provide superior durability, even in harsh
sensing environments rated to IP69K
Innovative dual-indicator system takes the guesswork out of sensor performance
monitoring
20 to 250V ac (3-wire hookup); SPST solid-state switch output, maximum
load 300 mA
Models
WARNING . . . Not To Be Used for Personnel Protection
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition.
Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for
personnel protection.
Seitenansicht 0
1 2 3 4 5 6 7

Inhaltsverzeichnis

Seite 1 - Features

Printed in USA 01/05 P/N 121515Q40 Sensors – ac-Voltage SeriesSelf-contained ac-operated sensors* Standard 2 m (6.5

Seite 2 - Sensor Setup

Q40 Sensors – ac-Voltage Series2 P/N 121515 Banner Engineering Corp. • Minneapolis, MN U.S.A.www.bannerengineering.com • Tel: 763.544.3164

Seite 3 - Color Sensitivity

P/N 121515 3 Q40 Sensors – ac-Voltage Series Banner Engineering Corp. • Minneapolis, MN U.S.A.www.bannerengineering.com • Tel: 763.544

Seite 4 - Specifications

Q40 Sensors – ac-Voltage Series4 P/N 121515 Banner Engineering Corp. • Minneapolis, MN U.S.A.www.bannerengineering.com • Tel: 763.544.3164

Seite 5 - Performance Curves

P/N 121515 5 Q40 Sensors – ac-Voltage Series Banner Engineering Corp. • Minneapolis, MN U.S.A.www.bannerengineering.com • Tel: 763.544