TM18 Series Sensors
Self-contained dc-operated photoelectric sensors in a robust metal housing
Sensing Range Model Range Cable* Output
Excess Gain Beam Pattern
Data taken at 25°
C
Diffuse
880 nm
Infrared
TM18BM6D
500 mm
(19")
2 m (6.5')
4-wire PVC
cable
Selectable
NPN or
PNP
TM18N6DQP
4-pin
Euro-style
150 mm (6")
polyurethane
(PUR)
pigtail QD
NPN
TM18P6DQP
PNP
Polarized Retroreflective
660 nm
Visible Red
TM18BM6LP
3 m
(10')
See
Note (1)
2 m (6.5')
4-wire PVC
cable
Selectable
NPN or
PNP
TM18N6LPQP
4-pin
Euro-style
150 mm (6")
polyurethane
(PUR)
pigtail QD
NPN
TM18P6LPQP
PNP
Models
WARNING . . .
Not To Be Used for Personnel Protection
Never usethese products as sensingdevices for personnel protection. Doing so could leadtoserious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your
current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
!
* For selectable NPN/PNP models, other cable/connector options are available:
9 m cable: add suffix “W/30” to the model number (e.g., TM18BM6D W/30)
4-pin Euro-style integral QD: add suffix “Q” to the model number (e.g., TM18BM6DQ)
(1) Retroreflective range is specified using one model BRT-84 reflector. Actual sensing range may be more or less than specified, depending
upon efficiency and reflective area of the reflector(s) in use. For example, using a BRT-92x92C reflector will increase range to 5 m.
Features
Robust die-cast nickel-plated housing with sealed membrane switch is designed to
meet IEC IP67 requirements
Excellent immunity to noise, including high-speed-switching fluorescent lamps and
EMI (electromagnetic interference)
Simple single-button setup procedure
Selectable light operate/dark operate (push-button toggle)
Models with selectable NPN or PNP operation (see hookups) or dedicated single
NPN or PNP output; 300mA current rating
Enhanced optical crosstalk avoidance
1
10
100
10 mm
0.4"
100 mm
4"
1000 mm
40"
1 mm
0.04"
1000
E
X
C
E
S
S
G
A
I
N
DISTANCE
TM18D
Diffuse Mode
625 mm
25"
500 mm
20"
375 mm
15"
250 mm
10"
125 mm
5"
0
0
20 mm
40 mm
60 mm
20 mm
40 mm
60 mm
0
0.8"
1.6"
2.4"
0.8"
1.6"
2.4"
DISTANCE
TM18D
Diffuse Mode
3.75 m
12.8'
3.0 m
10'
2.25 m
7.5'
1.5 m
5'
0.75 m
2.5'
0
0
20 mm
40 mm
60 mm
20 mm
40 mm
60 mm
0
0.8"
1.6"
2.4"
0.8"
1.6"
2.4"
DISTANCE
TM18LP
Polarized Retroreflective
with BRT-84 Reflector
E
X
C
E
S
S
G
A
I
N
DISTANCE
100
10
1
TM18LP
Polarized Retroreflective
with BRT-84 Reflector
0.01 m
.033'
0.1 m
.33'
1 m
3.3'
10 m
33'
1000
P
P
Feb 2013
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - TM18 Series Sensors

Printed in USA 04/05 P/N 69857 rev. ETM18 Series SensorsSelf-contained dc-operated photoelectric sensors in a robust metal housingSensing 

Seite 2 - TM18 Series Sensors – 

TM18 Series Sensors – Self-Contained Photoelectric Sensors in a Metal Housing2      P/N 69857 rev. E Banner Engineering Corp. • Minneapolis, MN U.S.A.

Seite 3

    P/N 69857 rev. E 3 TM18 Series Sensors – Self-Contained Photoelectric Sensors in a Metal HousingBanner Engineering Corp. • Minneapolis, MN U.

Seite 4

Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengi