350 Cable Survey System
DPN 402197 © TSS (International) Ltd Page 10 of 12
B.1.5.2 System Operation
When supplied as part of a complete Dualtrack System the SDC will have all the soft-
ware necessary to operate already installed and tested. After power-on the SDC will
perform an initialisation sequence and DeepView for Windows will then start automat-
ically.
Contact TSS for advice if you wish to upgrade an existing 440 or 350 System to a
Dualtrack.
1. Refer to this Manual and the 440 Manual for instructions to use DeepView for Win-
dows in its 440 and 350 modes.
2. Use the selection buttons on the DeepView for Windows tool bar to
select either the 440 or the 350 operating mode. These buttons are
available for use only if you select Dualtrack as the SEP type in the
System Configuration Wizard. The buttons are mutually exclusive –
you cannot operate the installation with the 440 System and the 350 System oper-
ating simultaneously.
3. DeepView for Windows annotates the internal logging file with the operating mode
so that it can replay the file correctly.
Note that the external logging file changes its format when you switch between the 440
and the 350 mode. Be aware that this might cause problems with the data logger and its
software.
B.1.6 Power Supply Requirement
CAUTION
You might cause permanent damage to the sub-sea installations of the 440 or the 350
System if you operate them from an incorrect electrical supply.
The standard sub-sea components of both Systems operate from a nominal 110V AC
electrical supply. Optionally, both Systems are available for operation from a nominal
240V AC electrical supply.
When you interconnect the 440 and the 350 Systems within a Dualtrack installation,
you must operate both Systems from the same electrical supply.
Specifications for the Dualtrack System are as listed in Section 8.1 of the relevant
Manual for the 440 and 350 Systems.
Note that the sub-sea components of the Dualtrack System must operate from the
same nominal supply voltage (either 110V or 240V AC as appropriate).
The maximum current consumption for the Dualtrack System is 3.1A at 110V AC
nominal electrical supply or 1.8A at 240V AC nominal electrical supply.