350 Cable Survey System
DPN 402197 © TSS (International) Ltd Page 4 of 14
Mount the SEP housing according to the following guidelines:
❐ Eliminate any possibility of snagging or damage to the SEP housing by installing it
inside the outer limits of the ROV frame.
❐ Locate the SEP housing so that you may install the cables easily between the
sub-assemblies of the 350 System.
❐ Do not apply sharp bends or other mechanical stresses to the cables during instal-
lation or operation. Route the cables between the components of the sub-sea
installation, and use plastic clips to secure them to the ROV frame.
❐ On small ROVs, position the SEP close to the centre of buoyancy to avoid upset-
ting the ROV trim.
❐ Tighten the mounting straps firmly so that the SEP housing cannot move under
the influence of ROV vibration or currents in the water.
❐ Refer to sub-section 4.1 for instructions to make the electrical connections
between the sub-sea components.
Figure 3–1: SEP mounting arrangement