350 Cable Survey System
DPN 402197 © TSS (International) Ltd Page 8 of 10
E.3 FAULT IDENTIFICATION
If the signal strength displayed on the Run Display screen does not show 1.0 to 1.5e6
at 25Hz for all channel check the following:
Check the condition of the battery in the coil tester. Press the power button and
confirm a constant green light. If a red or unlit LED is indicated, it is necessary to
replace the battery.
Check the display screen of the SDC is showing the channel under test. Note that
to display the port and starboard fore-aft channels (PF and SF respectively) the
Forward Search screen must be selected.
Check that the 350 System has been configured correctly with the coil calibration
constants for all six search coil channels. Check the values displayed on the SDC
correspond to their proper physical channels.
Check the Frequency Spectrum Display to make certain that all six channels are
receiving spurious signals from sources such as noise, mains frequency pickup,
etc. If there are no received signals, investigate a possible fault condition by refer-
ring to Section 9 Maintenance.
E.4 BATTERY REPLACEMENT
The Coil Tester includes a battery condition LED. Press the battery test switch on the
coil tester and check the LED first shows orange and then, after a short delay, shows
green. The LED should remain green while the switch is pressed to indicate the bat-
tery is in good condition.
If the LED goes red or doesn’t illuminate, replace the battery.
To replace the battery complete the following steps:
1. Unscrew the battery compartment end cap.
2. Remove the battery from its positioned secure clip.
3. Replace with a new battery and connect the battery connector.
4. Screw the battery compartment door back into place.
5. Press and hold down the power battery switch on the coil tester and confirm that
the battery condition LED shows the battery to be in a good condition.
The battery life for continuous use is estimated to be thirteen hours or three years in
stand-by mode.