5 – System Configuration
DPN 402197 © TSS (International) Ltd Page 7 of 10
The update rate for your System will reduce if you set a lower baud rate for this com-
munication link. You should consider reducing the baud rate for this link only if you
experience persistent communication problems caused by an umbilical cable of poor
quality. Ideally, in these circumstances you should swap to using an umbilical cable of
good quality instead.
At this point the software will provide an analysis of the data status and will provide
you with a summary screen of the findings that it has established.
Figure 5–2: DeepView for Windows - Summary
DeepView will now be configured to operate with the 350 System.
Before clicking on ‘Finish’ you have tick options to select:-
Show the pre-dive checklist when the System Configuration Window is closed.
Whether the System Configuration Wizard runs when DeepView for Windows
starts.
If the box is checked, the System Configuration Wizard will be run when DeepView for
Windows starts. If the box is not checked and if a configuration file is available, the
configuration file will be used to configure DeepView for Windows.
DeepView stores the configuration details automatically in an initialisation file when
DeepView is closing down. This allows the System to establish the same configura-
tion when you next power-on the SDC – provided it recognises the data format arriv-
ing from the SEP as being compatible with the stored configuration details. This
means that you should power-on the SEP before you power-on the SDC.